| MULTICHANNEL PIPETLER |
| | | 8 - Channel | 12 - Channel |
Multichannel Micropipettes • Non Autoclavable • Fully Autoclavable
Features • High accuracy and precision for 96-well microtitre plates. • Extended volume range upto 300µl. • Comfortable, light weight and soft plunger movement. • Seperate tip ejector allows easy tip ejection. • Recommended for ELISA, Molecule screening, Kinetic studies, DNA amplifications etc. Non Autoclavable Ordering Information and Specifications
• 8 - Channel Model | Vol. Range | Increments | Test Vol. | Inaccuracy | Imprecision | MC-8/10 | 0.5-10 | 0.1 µl | 1µl 5µl 10µl | 4.00% 2.50% 1.50% | 4.00% 2.50% 1.50% | MC-8/20 | 2-20 | 0.1 µl | 2µl 10µl 20µl | 4% 1.50% 1.50% | 4% 1.50% 1.00% | MC-8/50 | 5-50 | 1 µl | 5µl 25µl 50µl | 3.00% 1.50% 0.50% | 2.00% 1.00% 0.50% | MC-8/100 | 10-100 | 1 µl | 10µl 50µl 100µl | 1.50% 1.00% 1.00% | 1.50% 0.50% 0.50% | MC-8/300 | 40-300 | 1 µl | 40µl 150µl 300µl | 1.50% 1.00% 0.70% | 0.80% 0.50% 0.25% |
• 12 - Channel Model | Vol. Range | Increments | Test Vol. | Inaccuracy | Imprecision | MC-12/10 | 0.5-10 | 0.1 µl | 1µl 5µl 10µl | 4.00% 2.50% 1.50% | 4.00% 2.50% 1.50% | MC-12/20 | 2-20 | 0.1 µl | 2 µl 10 µl 20 µl | 4% 1.50% 1.50% | 4% 1.50% 1.00% | MC-12/50 | 5-50 | 1 µl | 5µl 25µl 50µl | 3.00% 1.50% 0.50% | 2.00% 1.00% 0.50% | MC-12/100 | 10-100 | 1 µl | 10 µl 50 µl 100 µl | 1.50% 1.00% 1.00% | 1.50% 0.50% 0.50% | MC-12/300 | 40-300 | 1 µl | 40µl 150µl 300µl | 1.50% 1.00% 0.70% | 0.80% 0.50% 0.25% |
| | 8 - Channel | 12 - Channel |
Fully Autoclavable Ordering Information and Specifications
• 8 - Channel Model | Vol. Range | Increments | Test Vol. | Inaccuracy | Imprecision | MCA-8/10 | 0.5-10 | 0.1 µl | 1µl 5µl 10µl | 4.00% 2.50% 1.50% | 4.00% 2.50% 1.50% | MCA-8/20 | 2-20 | 0.1 µl | 2µl 10µl 20µl | 4% 1.50% 1.50% | 4% 1.50% 1.00% | MCA-8/50 | 5-50 | 1 µl | 5µl 25µl 50µl | 3.00% 1.50% 0.50% | 2.00% 1.00% 0.50% | MCA-8/100 | 10-100 | 1 µl | 10µl 50µl 100µl | 1.50% 1.00% 1.00% | 1.50% 0.50% 0.50% | MCA-8/300 | 40-300 | 1 µl | 40µl 150µl 300µl | 1.50% 1.00% 0.70% | 0.80% 0.50% 0.25% |
• 12 - Channel Model | Vol. Range | Increments | Test Vol. | Inaccuracy | Imprecision | MCA-12/10 | 0.5-10 | 0.1 µl | 1µl 5µl 10µl | 4.00% 2.50% 1.50% | 4.00% 2.50% 1.50% | MCA-12/20 | 2-20 | 0.1 µl | 2 µl 10 µl 20 µl | 4% 1.50% 1.50% | 4% 1.50% 1.00% | MCA-12/50 | 5-50 | 1 µl | 5µl 25µl 50µl | 3.00% 1.50% 0.50% | 2.00% 1.00% 0.50% | MCA-12/100 | 10-100 | 1 µl | 10 µl 50 µl 100 µl | 1.50% 1.00% 1.00% | 1.50% 0.50% 0.50% | MCA-12/300 | 40-300 | 1 µl | 40µl 150µl 300µl | 1.50% 1.00% 0.70% | 0.80% 0.50% 0.25% |
|
| | |
|